WVRC-8 Installation and Operation Manual
OPERATION
The status alarms can be controlled by entering 97 followed by the status number 1
through 8 and 1 for enable, 0 of disable or 9 for poll.
The analog (metering) alarms can be controlled by entering 98 followed by the analog
number 1 through 8, and 1 for enable, 0 for disable or 9 for poll.
Power fail, silent sensor and temperature are controlled with 99 followed by 1 for power
fail, 2 for silent sensor and 3 for temperature. 1 to enable, 0 to disable or 9 to poll.
Some examples are listed below:
Enable Status 4 alarm: 9741
Disable Status 4 alarm: 9740
Poll Status 4 alarm enable: 9749
Enable Analog (metering) 5 alarm: 9851
Disable Analog (metering) 5 alarm: 9850
Poll Analog 5 alarm enable: 9959
Enable Power Fail Alarm: 9911
Disable Power Fail alarm: 9910
Poll Power Fail alarm enable: 9919
Enable Silent Sensor Alarm: 9921
Disable Silent Sensor Alarm: 9920
Poll Silent Sensor Alarm enable: 9929
Enable Temperature Sensor Alarm: 9931
Disable Temperature Sensor Alarm: 9930
Poll Temperature Sensor Alarm enable: 9939
NOTE: To clear an alarm, press the star (*) key.