SS 16.4 Installation and Operation Manual
CONTROLS
DIP (SW-24) Switch Functions
Switch Default
Number Setting Function
1 OFF Add 1 to Address (base address is 0)
2 OFF Add 2 to Address (base address is 0)
3 OFF Baud Rate: 00 - 9600, 01 - 2400, 10 - 19200, 11 - 38400
4 OFF Baud Rate: 00 - 9600, 01 - 2400, 10 - 19200, 11 – 38400
5 OFF Switching Mode
6 OFF Switching Mode
7 OFF Power up mode (Off = User programmable)
8 OFF Remote Control Mode (ON = Enables PIP)
Address (ID) DIP Switches
SW24 – 1 SW24 – 2 ID
OFF OFF ID = 0
ON OFF ID = 1
OFF ON ID = 2
ON ON ID = 3
Baud Rate DIP Switches
SW24 - 3 SW24 – 4 Baud Rate
OFF OFF 9600
ON OFF 2400
OFF ON 19200
ON ON 38400
Audio Switching Mode DIP Switches
SW24 - 5 SW24 – 6 Mode
OFF OFF Overlap
ON OFF Interlock
OFF ON Interlock
ON ON Mix
Power up/Last source DIP Switch
SW24 – 7 Function
OFF User Programmable
ON Last Source(s) selected
PIP/Remote Mode DIP Switch
SW24 - 8 Function
OFF Remote Control
ON PIP enabled
Front Panel Switches
Switch(es) Function
1-16 Channel Inputs
Output 1,2,3,4 Output selector
MUTE Mutes selected channel
MACRO Selects up to 16 Macro’s
Hidden “PGM” Special programming functions