Section 5: Module Configuration 5-23
Moseley SL9003Q 602-12016 Revision G
In a Transmitter
Relay 1 pins 7 (-) and 8 (+)
Tx control set OFF or transfer set COLD and unit is not Selected or Equipment Power
Off
Relay 1 = Off (Set Open)
Tx control set ON or AUTO or transfer set COLD and unit is selected and Equipment
Power On
Relay 1 = On (Set Closed)
Relay 2 pins 5 (-) and 6 (+)
Any Fault or Alarm or Equipment Power Off
Relay 2 = Off (Set Open)
No Faults or Alarms and Equipment Power On
Relay 2 = On (Set Closed)
In a Transceiver
Relay 1 pins 7 (-) and 8 (+)
Tx control set OFF or transfer set COLD and unit is not Selected or Equipment Power
Off
Relay 1 = Off (Set Open)
Tx control set ON or AUTO or transfer set COLD and unit is selected and Equipment
Power On
Relay 1 = On (Set Closed)
Relay 2 pins 5 (-) and 6 (+)
Any Fault or Alarm or Equipment Power Off
Relay 2 = Off (Set Open)
No Faults or Alarms and Equipment Power On
Relay 2 = On (Set Closed)
Relay 3 pins 3 (-) and 4 (+)
Receive RSL < -100dBm or Equipment Power Off
Relay 3 = Off (Set Open)
Receive RSL > -100dBm and Equipment Power On
Relay 3 = On (Set Closed)
Relay 4 pins 1 (-) and 2 (+)
Pre-BER> 1E-4 or Equipment Power Off
Relay 4 = Off (Set Open)
Pre-BER < 1E-4 and Equipment Power On
Relay 4 = On (Set Closed)