Section 4: Operation 4-29
Moseley SL9003Q 602-12016 Revision G
4.4.14 Radio RX Status
Function Settings Summary
Freq
948.0000 MHz Displays the receiver operating frequency
XMTR
TRAFFIC
FORCED (default)
Transfer status of receiver:
Is operating, ready for transfer
Is operating, will not transfer (forced ON)
RSL
-30.0 to -90.0 dBm Received signal level (signal strength)
Nominal level dependent upon customer
path/system gain
ATTEN
AUTO (default)
ON
OFF
Receiver PIN attenuator setting:
Controlled by internal software
Forced ON
Forced Off
SYNTH
LOCK (nominal)
UNLOCK
Indicates phase lock of the 1
st
LO
AFC
2.4 VDC (nominal) 1
st
LO PLL AFC Voltage
LO
100% (nominal) 1
st
LO relative power level